fire department signs .nyc

FDC Dry Standpipe Sign (Reflective, Aluminum, RED Background, 7X10 inch)

Write a Review
UPC:
782248331510
Availability:
In Stock
  • FDC Dry Standpipe Sign
  • FDC Dry Standpipe Signage
  • FDC Dry Standpipe
  • SIGN FDC Dry Standpipe
  • SIGNAGE FDC Dry Standpipe
  • BUILDING SIGNAGE FDC Dry Standpipe
$10.63
Frequently bought together:

Description

FDC Dry Standpipe Sign (Reflective,Aluminium, RED Background, 7X10 inch)-ref0420

Size: 10x7

Material: Aluminum

Backround color:Red

The "FDC Dry Standpipe Sign" serves as a crucial indicator for emergency responders, guiding them to the location of dry standpipe systems within buildings. These systems provide access points for firefighters to connect hoses and supply water to upper floors in the event of a fire where water is not readily available. By clearly marking the presence of these standpipes, this sign ensures that firefighters can swiftly deploy necessary equipment and initiate firefighting operations effectively. Additionally, it helps prevent confusion during emergencies and ensures that occupants and emergency personnel can quickly identify and utilize these critical firefighting resources. Thus, the presence of the "FDC Dry Standpipe Sign" is integral to enhancing emergency preparedness, facilitating efficient firefighting efforts, and ultimately saving lives and minimizing property damage in fire incidents.

 

Dry Standpipe Signs are designed to inform fire department officers and concerned parties of the type of sprinkler system in the building at hand. A dry standpipe system presents a network of in-place pipework allowing connections between a water supply (usually a fire department mobile apparatus known as a pumper) and a dedicated inlet at street level; With hose outlet valves on each floor.

 

Frequently asked Questions about dry standpipe and standpipe systems:

What is a dry standpipe ? With dry standpipes, the standpipe extends into the building to supply fire fighting water to the interior of the structure via hose outlets; Often located between each pair of floors in stairwells in high- rise buildings, dry standpipes are not filled with water until needed.

What is a manual dry standpipe? Automatic Dry Standpipe systems are only designed to have water in the system piping when the system is in use. Manual Dry Standpipe systems are for fire department use exclusively and require a fire department pumper to supply the needed pressure and water supply through a fire department connection

 

There are four types of standpipes that you will find in use:
·         Wet system with water in the pipes at all times; It is supplied by a water source. The pressure in the system is maintained constantly.
·         Automatic dry standpipe with air stored always inside the standpipe at a constant pressure; When a hose valve is opened, the air escapes allowing the water to enter into the standpipe system.
·         Semi-automatic dry standpipe with air stored inside the pipes, which can be either pressurized or not pressurized; With it water then enters the system, when an actuation device such as a manual pull station or an electrical switch is activated.
·         Manual dry standpipe system only with pipes feeding the system; With neither air nor water in them; For water to be supplied through the standpipe, a fire apparatus must be used.
 

FDC SIGNS- FIRE DEPARTMENT CONNECTION SIGNS:

FDC STAND FOR FIRE DEPARTMENT CONNECTION. The FDC signs designed to inform the 1st responded the location of the fire department connection in case of fire. The FDC is a connection on the exterior of a commercial building where a responding fire department can attach a fire hose and pump water into the building's stand pipe system supplementing the water pressure to the buidling's sprinkler system

FDC -Fire Department Connection-This is a connection on the exterior of a commercial building where a responding fire department can attach a fire hose and pump water into the building stand pipe system supplementing the water pressure to the building sprinkler system.

What is the purpose of FDC? The Fire Department Connection, also commonly known as the Siamese connection, is an important component found on most sprinkler and standpipe systems. When a fire sprinkler system activates, the FDC provides a means for firefighters to connect hose lines to supplement the fire sprinkler system's domestic water supply

What is a FDC sign? Fire Department Connection Signs to in complained with NFPA 14 Owners’ required to put FDC signs to mark standpipes and fire hose connections.

Which is the most common type of FDC connection? One of the most common FDCs, known as a Siamese or two-way connection, has two 2 1/2-inch female swivel connections. NFPA requires that all fire department connections use 2 1/2" National Hose (NH) threaded female couplings unless the authority having jurisdiction designates another specific connection type

 

 

Shipping and Handling Cost:

Our Shipping is fixed whether you buy 1 item or 20 items (We ship within USA only) - do not miss this opportunity to buy all signs needed at no additional shipping cost.

 

Sales Tax:

We are required to collect sales tax on any product sold on this site and shipped to an address in New York. The sales tax is 8.875 percent.

 

DISCLAIMER to comply with the New York City Consumer Protection Law which applies to all businesses operating in New York City: HPD-signs.com is a small family-owned and family-operated Brooklyn-based business. HPD-signs.com is not a City of New York store nor are the website, products or services affiliated with the City of New York or any agency of the City of New York. HPD-signs.com itself, its business, website, products, services, or any hyperlinks from its website are not sponsored by, approved by, affiliated with, endorsed by, or connected to the City of New York or any agency of the City of New York, including but not limited to HPD, DOB, DOT, DSNY, FDNY directly or by implication.

 

The requirements for sign content are determined by intended use and by applicable regulation. The BUYER is responsible for determining the appropriate content for a sign or package of signs. We makes no warranty or representation of suitability of a sign for any specific application. IT IS THE CUSTOMER'S RESPONSIBILITY TO ENSURE THAT THE SIGNS THE CUSTOMER ORDERS ARE IN COMPLIANCE WITH ALL STATE, FEDERAL, LOCAL, AND MUNICIPAL LAWS. Please review terms and conditions prior to purchase. 

The codes may not be the most recent version. The State / federal or other regulation department may have more current or accurate information. We make no warranties or guarantees about the accuracy, completeness, or adequacy of the information contained on this site or the information linked to on the state site. Please check official sources.

For more information about what is required, see the laws that are referenced and the rules applicable to your city and state. This page is for informational purposes only and is not intended as legal advice, professional advice or a statement of law. You may wish to consult with an attorney.

 

We provide both signs required by city and state regulation and Property Management Signs , DOB Signs , Hallway Signs , HPD Signs , Fire Department Signs , Floor Identification Signs , Door Signs , Building Directional Signs , Floor Number Signs , Building Signs , Silver Signs, ADA signs and many more in stock and ready to ship.

View AllClose

Warranty Information

The requirements for sign content are determined by intended use and by applicable regulation. The BUYER is responsible for determining the appropriate content for a sign or package of signs. HPDSigns.com makes no warranty or representation of suitability of a sign for any specific application. IT IS THE CUSTOMER'S RESPONSIBILITY TO ENSURE THAT THE SIGNS THE CUSTOMER ORDERS ARE IN COMPLIANCE WITH ALL STATE, FEDERAL, LOCAL, AND MUNICIPAL LAWS. Please review terms and conditions prior to purchase.
View AllClose
xyz1