MANUAL STANDPIPE FOR FIRE DEPARTMENT USE ONLY SIGN (Aluminium Reflective , RED 10x12)

Size: 10x12

Material: Aluminum

Color: White

 

A manual standpipe is an important component of a building's fire protection system. It is a pipe that connects to the main water supply and can be used by firefighters to manually pump water to a fire in the event that the building's sprinkler system fails. This "Manual Standpipe for Fire Department Use Only" sign is designed to be highly visible and legible, with bold white letters on a red background. Measuring 10x12 inches, it is the perfect size to be easily noticed and read from a distance.

Made from high-quality aluminum, this sign is built to last. It is resistant to rust, corrosion, and fading, ensuring that it remains visible and legible for many years to come. The reflective surface of the sign ensures that it can be seen even in low light conditions, making it an ideal option for both indoor and outdoor use.

This sign is an important safety measure that helps to ensure that the manual standpipe is only used by the fire department. It is particularly useful in areas where the manual standpipe may be located in an out-of-the-way location or where there is a risk that it may be accidentally used by someone who is not trained to do so. By installing this sign, you can help prevent the manual standpipe from being used improperly and ensure that it is always ready for use by the fire department in the event of a fire.

This sign is suitable for use in a wide range of settings, including commercial buildings, industrial facilities, hospitals, and more. It is easy to install, with pre-drilled holes that allow for quick and simple mounting. By investing in this "Manual Standpipe for Fire Department Use Only" sign, you can help improve the safety of your building and protect the lives and property of those inside.

 

Our standpipe signs – Design to inform 1st responded about the standpipe system in the building and their locations. A Standpipe system is a series of pipes which connect a water supply to hose connections, basically an extension of the fire hydrant system. They are designed to provide a pre-piped water system for building occupants or the fire department.

A standpipe system is An arrangement of piping, valves hose connections and other equipment installed in a building or structure, with the hose connections located in such a manner that water can be discharged in streams through attached hose and nozzles, for the purposes of extinguishing a fire, thereby protecting a building or structure and its contents in addition to protecting the occupants. This is accomplished by means of connections to water supply systems or by means of pump tanks and other equipment necessary to provide an adequate supply of water to the hose connections.”

It is, essentially, a way of delivering water from one area of the structure or facility to another so that we can fight the fire while at the same time shortening the length of the supply and attack lines. Standpipes can be an intricate or simple system, but the result is the same: water delivery. These systems can be vertical (which is the common type) or they can be horizontal.   

Below are four types of standpipes that you will find in use:

  • Wet system. Here, water is in the pipes at all times and is supplied by a water source. The pressure in the system is constantly maintained.
  • Automatic dry standpipe. Here, there is always air stored inside the standpipe at a constant pressure. When a hose valve is opened, the air escapes allowing the water to enter into the standpipe system.
  • Semi-automatic dry standpipe. In this system, air is stored inside the pipes, which can be pressurized or not be pressurized. Once an actuation device such as a manual pull station or an electrical switch is activated, water then enters the system.
  • Manual dry standpipe. This type of system has only pipes feeding the system with no air or water in them. A fire apparatus must be used to supply the water through the standpipe.

 

Shipping and Handling Cost:

Our Shipping is fixed whether you buy 1 item or 20 items (We ship within USA only) - do not miss this opportunity to buy all signs needed at no additional shipping cost.

 

Sales Tax:

We are required to collect sales tax on any product sold on this site and shipped to an address in New York. The sales tax is 8.875 percent.

 

DISCLAIMER to comply with the New York City Consumer Protection Law which applies to all businesses operating in New York City: HPD-signs.com is a small family-owned and family-operated Brooklyn-based business. HPD-signs.com is not a City of New York store nor are the website, products or services affiliated with the City of New York or any agency of the City of New York. HPD-signs.com itself, its business, website, products, services, or any hyperlinks from its website are not sponsored by, approved by, affiliated with, endorsed by, or connected to the City of New York or any agency of the City of New York, including but not limited to HPD, DOB, DOT, DSNY, FDNY directly or by implication.

 

The requirements for sign content are determined by intended use and by applicable regulation. The BUYER is responsible for determining the appropriate content for a sign or package of signs. We makes no warranty or representation of suitability of a sign for any specific application. IT IS THE CUSTOMER'S RESPONSIBILITY TO ENSURE THAT THE SIGNS THE CUSTOMER ORDERS ARE IN COMPLIANCE WITH ALL STATE, FEDERAL, LOCAL, AND MUNICIPAL LAWS. Please review terms and conditions prior to purchase. 

The codes may not be the most recent version. The State / federal or other regulation department may have more current or accurate information. We make no warranties or guarantees about the accuracy, completeness, or adequacy of the information contained on this site or the information linked to on the state site. Please check official sources.

For more information about what is required, see the laws that are referenced and the rules applicable to your city and state. This page is for informational purposes only and is not intended as legal advice, professional advice or a statement of law. You may wish to consult with an attorney.

 

We provide both signs required by city and state regulation and Property Management Signs , DOB Signs , Hallway Signs , HPD Signs , Fire Department Signs , Floor Identification Signs , Door Signs , Building Directional Signs , Floor Number Signs , Building Signs , Silver Signs, ADA signs and many more in stock and ready to ship.

 

 

View AllClose

Warranty Information

The requirements for sign content are determined by intended use and by applicable regulation. The BUYER is responsible for determining the appropriate content for a sign or package of signs. HPDSigns.com makes no warranty or representation of suitability of a sign for any specific application. IT IS THE CUSTOMER'S RESPONSIBILITY TO ENSURE THAT THE SIGNS THE CUSTOMER ORDERS ARE IN COMPLIANCE WITH ALL STATE, FEDERAL, LOCAL, AND MUNICIPAL LAWS. Please review terms and conditions prior to purchase.
View AllClose
xyz1